Loading...
Admin Approval 10-18-22 Screening Wall DetailSTEEL SLEEVE SLIPPED OVER AND WELDED TO 6" DIA. STEEL PIPE PAINTED 1 1/2" X 1 1/2" STEEL ANGLE DIAGONAL BRACING GREASE FITTINGS, TYP. PAINTED STEEL PIPE GATE SLEEVE HINGE TO FIT OVER STEEL POST STEEL CHANNEL FRAME, PAINT. 6"X6"X4" STEEL PLATE 6" DIA. X 3/8" PAINTED STEEL TUBE SUPPORT. FILL / CONC AND DOME TOP TO ENDURE POSITIVE DRAINAGE PAVEMENT REF. CIVIL CONCRETE FOOTING SLOPE SURFACE AWAY FROM FOOTING 6" DIA. CONCRETE FILLED GALV. PIPE BOLLARD, PAINT TO MATCH STC-01 CONCRETE WASH DOME PROVIDE SMOOTH ROUND SURFACE #3 BARS x 10" THROUGH PIPE 3" 3' - 0"4' - 0"5" 6" 5" CONCRETE WALK RAMPS ALL SIDES 1:12 MAX SLOPE NOTE: REF. CIVIL FOR RAMP DIMENSIONS. MUST COMPLY WITH TAS REQUIREMENTS 5' - 0" 1/4"W TOOLED JOINT, 1/4 DEPTH OF SLAB, SEALANT IN JOINT BROOM FINISH PERPENDICULAR TO DIRECTION OF TRAVEL CONCRETE SIDEWALK, COORD. W/ GEOTECH REPORT, REF. CIVIL FOR ADDITIONAL DETAILS AND LOCATIONS ENGINEERED FILL, REF. GEOTECH REPORT BACKER ROD & SEALANT IN 1/2" EXPANSION JOINT @ 20'-0" O.C. MAX. RE: CIVIL BROOM FINISH PERPENDICULAR TO DIRECTION OF TRAVEL, TYP. CONCRETE SIDEWALK, COORD. W/ GEOTECH REPORT, REF. CIVIL FOR ADDITIONAL DETAILS AND LOCATIONS ENGINEERED FILL, REF. GEOTECH REPORT 3/8" PRE-FORMED JOINT FILLER FIRST POUR SECOND POUR LEVEL 00 -4' -6" PREFIN. METAL CAP FLASHING LAP 4" OR GREATER, W/ CONCEALED FASTENERS ON WOOD BLOCKING AS REQUIRED, SLOPE TO DRAIN BOND BEAM RE: STRUCT. 8" REINFORCED CMU, PAINT INSIDE FACE COLOR TBD. ENCLOSURE FOUNDATION SLAB. RE: STRUCT. 6 AS1.21 14' - 0"0' - 1"ELEVATED PLATFORM W/ GUARD RAIL, RE: STRUCT. FOR ADDITIONAL DETAIL. 10 YARD COMPACTOR CONC. FLATWORK RE: CIVIL 8" REINFORCED CMU, PAINT INSIDE FACE COLOR TBD. GALV. PERF MTL GATE, RE: STRUCT. HSS TUBES RE: STRUCT. (MODEL AS 6X6X1/2 PAINTED PIPE BOLLARD DUMPSTER SCREEN WALL COLOR TO MATCH EXISTING BUILDING, RE: STRUCTURAL FOR SUPPORTS THIS DOCUMENT HAS BEEN PROVIDED FOR REVIEW OF DESIGN-BUILD SCOPE OF WORK AND REGULATORY APPROVAL. IT IS NOT INTENDED FOR BIDDING OR CONSTRUCTION BY ANY CONTRACTOR OTHER THAN BRANDT WITHOUT THE WRITTEN APPROVAL OF BRANDT. . SHEET NUMBER DESIGN-BUILD DOCUMENT BRANDT JOB NUMBER DALLAS 1728 BRIERCROFT CT. CARROLLTON, TX 75006 972-395-6000 THE BRANDT COMPANIES, LLC TEXAS BOARD OF PROFESSIONAL ENGINEERS FIRM REGISTRATION NUMBER F1723 ON THIS DATE: ENGINEER'S SEAL THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INFORMATION ONLY, IT IS NOT TO BE USED FOR PERMIT OR CONSTRUCTION. UNDER AUTHORITY OF: RODNEY RAMSEY - P.E. 91960 DALLAS 211 N. ERVAY, SUITE 610 DALLAS, TX 75201 314-302-6864 MODUS ARCHITECTURE, PLLC 07.29.2022 AS1.21 SITE DETAILSPATHGROUP LAB RENOVATION1111 NORTHPOINT, COPPELL, TX 7501922-00209 07/29/2022 1 1/2" = 1'-0"2 DETAIL - GATE HINGE 3/4" = 1'-0"4 PIPE BOLLARD DETAIL 1/2" = 1'-0"5 DETAIL - CURB RAMP 3" = 1'-0"3 DETAIL - SIDEWALK CJ 3" = 1'-0"1 DETAIL - SIDEWALK EJ 1/2" = 1'-0"6 SECTION - DUMPSTER ENCLOSURE 1/8" = 1'-0"7 ELARGED PLAN - DUMPSTER #ISSUE FOR PERMIT07/29/2022-NOT TO SCALE8SCREEN WALL ADMINISTRATIVELY APPROVED October 18, 2022