Loading...
updated utiltiy plan_8-3-22-THEE ROAD ESTATES PH 2 LOT 1 R, BLOCK 1 VOL. 2003252, PG. 111 E "AE': ZONE 'AE" � ELEV= 495' tis�O9, i BLOT K 1 BIG CEDAR ADDITION VOL. 95226, PG. 2280 LOT 9 R DAVID & APRIL TERRY INST. 201000276998 TRIBUTARY G-1 (OF GRAPEVINE CREEK) LOT 8 R LAURA BARNETT INST. 2002023511 S84'4� 160.67' ZONE "AE" SDI LLI S=I =1 II$ ISI I=S I � I � .� S �� Tta:rcc:r* IxZi al IIA IV I I � � 111 i� APPROX. LOCATION \ ZONE AE 100VR APPROXIMATE LOCATION _ EROSION HAZARD SETBACK I�i \ PER CITY ORDINANCE I I I I I INSTALL1 1" DOMESTIC WATER LINE TO HOUSE 30' BLDGISETBACK I I II � EXISTING 1" WATER METER TO REMAIN dHO - dHO - dH0 OHP OHP -OHP - OH OHP -OHP -OHP -OHP OHP G G G G OVERALL 50,653 SQ. FT. 1. 163 ACRES S89'59'26"E 270.02' NEW BUILDING 4,000 SF FIFE = 506.6 N,- 48113CO135K DATE 0710712014 WEST BETHEL (50' RIGHT-OF-WAY) 12"PVC —S— —S S� S S S S s s S S S— SD SD SD SD SD SD SD SD SD SD — 16"RCCP D4 w w w 16"RCCP w w —w— w w w w w- - C—u— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — //NCHMARK#1: I EN]w ,goo• PROPOSED ADDITION EXISTING HOME EXISTING 1 BETHEL ROAD ESTATES STRUCTURE LOT 1, BLOCK 1 VOL. 2000134, PG. 2875 �S FURNISH AND INSTALL 4" SANITARY SEWER LINE TO PROPOSED BUILDING -w U) FURNISH AND INSTALL NEW 4" SANITARY SEWER CLEANOUT PER CITY STD. DETAIL 5120 S101'20"W 7.35' S89'42'02"W 130.02' HP HH VERIZON BOX 12"PVC S S S S S S SD w w w EXISTING 4" SEWER SERVICE TO REMAIN. CONTRACTOR TO VERIFY EXISTING LINE IS IN GOOD WORKING ORDER VIA VIDEO OR OTHER ACCEPTABLE MEANS. Know what's below. Call before you dig. KAYE ST. COPPER LN. 0 d BROOKS LN. NCL (N W Q Z O a = w 0 U 0 PROJECT F-1-1 LOCATION BETHEL RD 0 o: J W a a 0 U VICINITY MAP N.T.S. pvo UTILITY CONSTRUCTION NOTES 1. CONTRACTOR SHALL OBTAIN A CONSTRUCTION DEVELOPMENT PERMIT FOR ANY WORK WITHIN THE CITY OF COPPELL. 2. CONTRACTOR SHALL REVIEW THE SITE MECHANICAL AND PLUMBING PLANS PRIOR TO ANY CONSTRUCTION TO INSURE THAT THE PROPOSED UTILITIES SHOWN ON THESE PLANS ARE IN PROPER ALIGNMENT AND DEPTH. 3. ALL CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE STANDARD SPECIFICATIONS OF THE CITY OF COPPELL. 4. CONTRACTOR SHALL BE REQUIRED TO PROVIDE AND MAINTAIN ALL NECESSARY WARNING AND SAFETY DEVICES (FLASHING LIGHTS, BARRICADES, SIGNS, ETC.) TO PROTECT THE PUBLIC SAFETY AND HEALTH UNTIL THE WORK HAS BEEN COMPLETED AND ACCEPTED BY THE CITY. 5. ALL PIPES SHALL BE KEPT FREE OF TRASH AND DIRT AT ALL TIME. AT THE END OF EACH DAY, THE PIPE SHALL BE TEMPORARILY SEALED/CONNECTED. ALL PIPE INSTALLATION SHALL BE PERFORMED AS RECOMMENDED PER THE PIPE MANUFACTURER. THE CONTRACTOR SHALL INSPECT THE SITE DAILY AND KEEP THE SITE FREE OF TRASH AND CONSTRUCTION DEBRIS. 6. THE CONTRACTOR SHALL CONTACT THE ASSIGNED INSPECTOR FOR THE OPERATION OF ALL WATER VALVES & SCHEDULING OF SERVICES BY WATER/WASTEWATER. 7. INSTALL WATER PIPE TO PROVIDE 12" MIN. CLEAR OF ALL PROPOSED AND EXISTING PIPING. 8. THE CONTRACTOR SHALL MAINTAIN THE EXISTING WATER MAINS AND SERVICES IN OPERATION WHEN INSTALLING NEW WATER MAINS. THIS SHALL INCLUDE ANY TEMPORARY CONNECTIONS, IF REQUIRED. 9. SEWER LATERALS SHALL BE INSTALLED PER COPPELL STANDARD DETAIL 5110. 10. THE CONSTRUCTION OF SEWER LATERALS SHALL COMMENCE AT THE LOWEST POINT OF THE SYSTEM (I.E. AT A MANHOLE OR THE END OF AN EXISTING MAIN). THE INSTALLATION OF SEWER LATERALS SHALL ALWAYS PROCEED UPSTREAM IN ALL LOCATIONS. 11. ALL TRENCHES SHALL BE BACKFILLED AND REPAIRED PER CITY STANDARDS. 12. CONTRACTOR SHALL VERIFY EXACT LOCATION AND DEPTH OF EXISTING SANITARY SEWER MAIN IN THE FIELD PRIOR TO THE CONSTRUCTION OF THE PROPOSED SANITARY SEWER LINE TO BE CONNECTED. CONTRACTOR SHALL NOTIFY MBW ENGINEERING IF THE DESIGN AS SHOWN IS NOT ACHIEVABLE. 13. SANITARY SEWERLINE MINIMUM DIAMETER SHALL BE 8". SERVICE LATERALS SHALL HAVE A MINIMUM DIAMETER OF 4". s s 14. SANITARY SEWER LINE INSTALLATIONS MAY BE SUBJECT TO INFILTRATION TESTING, EXALTRATION TESTING, MANDREL TESTING AND LOW PRESSURE AIR TESTING IN ACCORDANCE WITH THE TEXAS ADMINISTRATIVE CODE RULE 317.2. 3. ALL SANITARY SEWERLINE INSTALLATIONS SHALL HAVE A TV EXAMINATION PERFORMED. A COPY OF SAID EXAMINATION SHALL BE PROVIDED TO THE CITY FOR REVIEW PRIOR TO ACCEPTANCE OF THE SANITARY SEWER LINE BY THE CITY. — — — — _ 15. MANHOLES SHALL BE VACUUM TESTED IN ACCORDANCE WITH NCTCOG CONSTRUCTION METHOD 502.1.5.2. 16. SANITARY SEWERLINE INSTALLATIONS THAT CROSS OR CLOSELY PARALLEL A WATERLINE SHALL BE DESIGNED IN ACCORDANCE WITH THE TEXAS ADMINISTRATIVE CODE RULE 317.2. 17. SANITARY SEWERLINE EMBEDMENT SHALL BE IN ACCORDANCE WITH THE CITY OF COPPELL STANDARD CONSTRUCTION DETAIL 3050. 18. WATER EMBEDMENT SHALL BE IN ACCORDANCE WITH THE CITY OF COPPELL STANDARD CONSTRUCTION DETAIL 3030. 19. ALL WATER AND WASTEWATER LINES SHALL BE SEPARATED PER TCEQ RULES AND REGULATIONS AND SHALL CONFORM TO CHAPTER 290 — PUBLIC DRINKING WATER SUBCHAPTER D: RULES AND REGULATIONS FOR PUBLIC WATER SYSTEMS SS290.38-290.47 AND CHAPTER 217 — DESIGN CRITERIA FOR DOMESTIC WASTEWATER SYSTEMS SUBCHAPTER C: CONVENTIONAL COLLECTION SYSTEMS SS217.51-217.70. PRELIMINARY UTILITY PLAN C 2022 GPF Architects LLC 549 E. SANDY LAKE ROAD SUITE 100 COPPELL, TEXAS 75019 TEL: (972 )824-7966 NO PART OF THIS DRAWING MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM OR TRANSMITTED IN ANY FORM OR BY ANY MEANS, MECHANICAL, ELECTRONIC, PHOTOCOPYING, RECORDING OR OTHERWISE WITHOUT THE PRIOR WRITTEN PERMISSION OF THE ARCHITECT. CONSULTANTS CIVIL ENGINEER MBW ENGINEERING, LLC 4924 BOLERO COURT FT. WORTH, TEXAS LANDSCAPE ARCHITECT AWR DESIGNS, LLC P.O. BOX 1746 ALEDO, TX 76008 Qp�S 0 F �i IE!SE P S Alk OT L --00-00 LLJ LLJ o 0 'n C) 00 W o0 z O �� r*-- Q � Q LLJ i U O =Q WX W LLJ m Ld Q Z � J W J z �� Q O O a- Cn W (.00 O J 0 REVISIONS BY DATE ISSUE FOR DRC 08 03 22 DRAWN MW CHECKED MW SCALE AS SHOWN JOB NO. 8057 SHEET C1 001 OF SHEETS